• Skip to primary navigation
  • Skip to main content

Dr. Kyle Stanley

Speaker | Educator | Dental Expert

  • Home
  • Speaking Events
  • Topics
  • Publications
  • Galleries
  • Contact Dr. Stanley

Mechanical integrity of cement and screw-retained zirconium-lithium silicate glass-ceramic crowns to morse taper implants

Mechanical integrity of cement- and screw-retained zirconium-lithium silicate glass-ceramic crowns to Morse taper implants.

 

STATEMENT OF PROBLEM:

The improved esthetics of ceramic dental prostheses has increased their popularity, although their high elastic modulus and low fracture toughness and tensile strength may reduce the long-term performance of dental prostheses.

PURPOSE:

The purpose of this in vitro study was to assess the mechanical integrity of zirconium-lithium silicate glass-ceramic crowns cement- and screw-retained to a titanium implant-abutment after fatigue.

MATERIAL AND METHODS:

Forty titanium implants were placed in polyacetal to mimic bone support. Abutments were tightened to the implants to 20 Ncm by using a digital handheld torque meter. The implant abutment assemblies received a pressed maxillary premolar crown, either lithium disilicate (LD) or zirconium-lithium silicate glass-ceramic (LZS). The specimens (n=10) were subjected to fatigue at 200 N and 5 Hz for 500 000 cycles in a Ringer electrolytic solution (37°C). After fatigue, the crowns were removed to evaluate removal torque values on the implant-abutment connection. The remaining crown-implant-abutment assemblies were cross-sectioned at 90 degrees to the implant-abutment joint for inspection of cracks and the micro-gaps by scanning electron microscopy.

RESULTS:

Removal torque values before fatigue were recorded at 18 ±1.63 Ncm for the LD group and 18.2 ±0.81 Ncm for the LZS group. After fatigue, the removal torque values decreased significantly (12.8 ±1.6 Ncm for LD, 14.9 ±1.08 Ncm for LZS; P<.05). Micro-gaps at the implant-abutment connections were measured at 0.9 ±0.3 μm before fatigue and at 4.2 ±0.9 μm after fatigue. Cracks were detected at the crown adhesive or at the adhesive-abutment interface for both systems after fatigue.

CONCLUSIONS:

Cement- and screw-retained implant zirconium-lithium silicate glass-ceramic crowns revealed effective fatigue resistance on mean cyclic loading in an electrolyte solution. However, mechanical instability of the crown-adhesive-abutment interfaces and implant-abutment joints was detected after fatigue.

Related

Copyright © 2023 · Kyle Stanley - All Rights Are Reserved ·